Adding hp-insightmanager to debian
Tue 13 January 2015
HP Specific HP servers allow you to install insigt manager this gives you lots of information on the servers running conditions. I have prepared a file which includes the latest
//ntserv3/Install/HP Servers
There is two files one is the tgz file and the other is a gpg footprint ` gpg —print-md sha512 hp-insightmanager+tools.tgz If you do this hp-insightmanager+tools.tgz: 1AAD552B 72AA0EBE C29CEDB7 46BB3A5F 3AF620E1 1A2F769B 895D14C9 EED56228 33A99EBF 8D0FB9FF 47AB60E7 C3285E32 ED4863E4 78BEE052 D21E563C 44FCB06B and get that then its ok to install and use
aptitude install iproute
aptitude install snmpd
aptitude install libstdc++2.10-glibc2.2 (when version < lenny)
aptitude install ethtool
dpkg -i libstdc++2.10-glibc2.2 (when version is lenny or up)
dpkg -i hpsmh-2.1.7-167.debian.i386.deb
dpkg -i hpasm-7.8.0-100.etch26.i386.deb
dpkg -i hpadu-7.80-4.linux.deb
dpkg -i hpacucli-7.80-3.linux.deb
dpkg -i cpqacuxe-7.80-4.linux.deb
dpkg -i cmanic_7.9.0-5b.etch_i386.deb
/etc/init.d/hpasm reconfigure
` (SNMP Read/Write community string: argoss)
Using the tools to check status
` tardis:/# hpacucli HP Array Configuration Utility CLI 7.80-3.0 Detecting Controllers…Done. Type “help” for a list of supported commands. Type “exit” to close the console.
=> controller slot=3 physicaldrive all show status physicaldrive 1:1 (box 1:bay 1, 750 GB): OK physicaldrive 1:2 (box 1:bay 2, 750 GB): OK physicaldrive 1:3 (box 1:bay 3, 750 GB): OK physicaldrive 1:4 (box 1:bay 4, 750 GB): OK physicaldrive 1:5 (box 1:bay 5, 750 GB): OK physicaldrive 1:6 (box 1:bay 6, 750 GB): OK physicaldrive 1:7 (box 1:bay 7, 750 GB): OK physicaldrive 1:8 (box 1:bay 8, 750 GB): OK physicaldrive 1:9 (box 1:bay 9, 750 GB): OK physicaldrive 1:10 (box 1:bay 10, 750 GB): OK physicaldrive 1:11 (box 1:bay 11, 750 GB): OK physicaldrive 1:12 (box 1:bay 12, 750 GB): OK physicaldrive 2:1 (box 2:bay 1, 750 GB): OK physicaldrive 2:2 (box 2:bay 2, 750 GB): OK physicaldrive 2:3 (box 2:bay 3, 750 GB): OK physicaldrive 2:4 (box 2:bay 4, 750 GB): OK physicaldrive 2:5 (box 2:bay 5, 750 GB): OK physicaldrive 2:6 (box 2:bay 6, 750 GB): OK physicaldrive 2:7 (box 2:bay 7, 750 GB): OK physicaldrive 2:8 (box 2:bay 8, 750 GB): OK physicaldrive 2:9 (box 2:bay 9, 750 GB): OK physicaldrive 2:10 (box 2:bay 10, 750 GB): OK physicaldrive 2:11 (box 2:bay 11, 750 GB): OK physicaldrive 2:12 (box 2:bay 12, 750 GB): OK And the controller
=> controller slot=3 show status
Smart Array P800 in Slot 3 Controller Category: OK Cache Category: OK Battery Category: OK NB: On tardis there is two controllers slot=1 and slot=3 slot one is the system disks and slot three is the MSA60 `