HP Specific HP servers allow you to install insigt manager this gives you lots of information on the servers running conditions. I have prepared a file which includes the latest
//ntserv3/Install/HP Servers
There is two files one is the tgz file and the other is a gpg footprint ` gpg --print-md sha512 hp-insightmanager+tools.tgz If you do this hp-insightmanager+tools.tgz: 1AAD552B 72AA0EBE C29CEDB7 46BB3A5F 3AF620E1 1A2F769B 895D14C9 EED56228 33A99EBF 8D0FB9FF 47AB60E7 C3285E32 ED4863E4 78BEE052 D21E563C 44FCB06B and get that then its ok to install and use
` (SNMP Read/Write community string: argoss)
Using the tools to check status
` tardis:/# hpacucli HP Array Configuration Utility CLI 7.80-3.0 Detecting Controllers...Done. Type "help" for a list of supported commands. Type "exit" to close the console.
=> controller slot=3 physicaldrive all show status physicaldrive 1:1 (box 1:bay 1, 750 GB): OK physicaldrive 1:2 (box 1:bay 2, 750 GB): OK physicaldrive 1:3 (box 1:bay 3, 750 GB): OK physicaldrive 1:4 (box 1:bay 4, 750 GB): OK physicaldrive 1:5 (box 1:bay 5, 750 GB): OK physicaldrive 1:6 (box 1:bay 6, 750 GB): OK physicaldrive 1:7 (box 1:bay 7, 750 GB): OK physicaldrive 1:8 (box 1:bay 8, 750 GB): OK physicaldrive 1:9 (box 1:bay 9, 750 GB): OK physicaldrive 1:10 (box 1:bay 10, 750 GB): OK physicaldrive 1:11 (box 1:bay 11, 750 GB): OK physicaldrive 1:12 (box 1:bay 12, 750 GB): OK physicaldrive 2:1 (box 2:bay 1, 750 GB): OK physicaldrive 2:2 (box 2:bay 2, 750 GB): OK physicaldrive 2:3 (box 2:bay 3, 750 GB): OK physicaldrive 2:4 (box 2:bay 4, 750 GB): OK physicaldrive 2:5 (box 2:bay 5, 750 GB): OK physicaldrive 2:6 (box 2:bay 6, 750 GB): OK physicaldrive 2:7 (box 2:bay 7, 750 GB): OK physicaldrive 2:8 (box 2:bay 8, 750 GB): OK physicaldrive 2:9 (box 2:bay 9, 750 GB): OK physicaldrive 2:10 (box 2:bay 10, 750 GB): OK physicaldrive 2:11 (box 2:bay 11, 750 GB): OK physicaldrive 2:12 (box 2:bay 12, 750 GB): OK And the controller
=> controller slot=3 show status
Smart Array P800 in Slot 3 Controller Category: OK Cache Category: OK Battery Category: OK NB: On tardis there is two controllers slot=1 and slot=3 slot one is the system disks and slot three is the MSA60 `
For any feedback or corrections, please write in to: Simon Quantrill